Conveyor switch

Explosion proof bidirectional rope switch HSBG-V3931ABX-IISPS-2D

The explosion-proof bidirectional rope switch HSBG-V3931ABX-II is widely used in various conveying equipment specialized in bulk material transportation in fields such as metallurgy, coal, cement, mining, power, ports, and chemical industry.

  • Explosion proof bidirectional rope switch HSBG-V3931ABX-II
  • ZHUOXIN
  • 24-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • The explosion-proof bidirectional rope switch HSBG-V3931ABX-II is widely used in various conveying equipment specialized in bulk material transportation in fields such as metallurgy, coal, cement, mining, power, ports, and chemical industry.

Description

Conveyor switch

Explosion proof bidirectional pull rope switch HSBG-V3931ABX-II Explosion proof bidirectional pull rope switch HSBG-V3931ABX-II Explosion proof bidirectional pull rope switch HSBG-V3931ABX-II Explosion proof bidirectional pull rope switch BKLT2-II Installation instructions
1. The pull rope switch is installed in pairs on both sides of the belt conveyor. Drill a 12mm hole on the iron frame next to the belt conveyor and tighten the pull rope switch with M10 × 40mm bolts< br/>2、 Install one drawstring switch every 40 meters, and its position should be lower than the belt and convenient for on-site workers to use< br/>3、 The pull rope is tied to the first arm, and it is recommended to use plastic coated steel wire rope with a diameter of 3-5mm. The steel wire rope is fixed with a rope clamp, and a support ring is installed every 3 meters to prevent excessive sag of the steel wire rope and ensure reliable rope pulling action. Under the premise of ensuring normal operation of the switch, try to tighten the rope as much as possible to reduce the sag deflection of the steel wire rope< br/>4、 For the climbing section of the belt conveyor, the distance between the pull rope switches and the length of the pull rope should be minimized as much as possible< br/>5、 Wiring: The rope switch is equipped with a 1.2-meter-long four core rubber sleeve cable when leaving the factory. The core wire is equipped with wire numbers 1, 2, 3, and 4, where 1 and 2 are normally open contacts for alarm signals and 3 and 4 are normally closed contacts for shutdown signals< Accessories: Plastic coated steel wire rope, rope clamp and steel wire rope support ring, installation bracket, etc. are all sold as LJG5C-4/Z2CN2, LJG5C-4/Z2BN2 , LJG5C-4/Z2CP2 , LJG5C-4/Z2BP2 , LJG5C-4/Z0AN2 LJG5C-4/Z0BN2 , LJG5C-5/Z2CN2 , LJG5C-5/Z2BN2 , LJG5C-5/Z2CP2, LJG5C-5/Z2BP2   LJG5C-5/Z0AN2 , LJG5C-5/Z0BN2 , LU3-10N1, LU3-10N2 , LU3-10P1, LU3-10P2,LU4-16N1 ,     LU4-16N2, LU4-16P1, LU4-16P2, LU4-16D1, LU4-16D2,LU5-16N1, LU5-16N2, LU5-16P1    LU5-16P2, LU5-16D1, LU5-16D2, JKS-J-D,LU5-15N1,LU5-15N2, LU5-15P1,LU5-15P2   LU5-15D1, LU5-15D2, JKD-J-D12,SK-3015A,SK-3015B,SK-3015AB, SK-3015C,SK-3015D SK-3015CD, SK-3015AL, SK-3015BL,SK-2015A,SK-2015B,SJ-3018A,SJ-3018B, SJ-3018AB, SJ-3018C,SJ-3018D,SJ-3018CD,SJ-3018AL,SJ-3018BL,SJ-2018A,SJ-2018B,SD-3020A,SD-3020B,SD-3020AB,SD-3020C,SD-3020D,SD-3020CD,SD-3020AL,SD-3020BL,SD-2020A,SD-2020B, SD-2020AB SE-3025A SE-3025B SE-3025AB&nbp; SE-3025C SE-3025D, SE-3025CD&nbp; SE-3025AL, SE-3025BL, SE-2025A, SE-2025B, SE-2025AB, TCO-3040A, TCO-3040B TCO-3040AB, TCO-3040C, TCO-3040CD, TCO-3040AL, TCO-3040BL, TCO-2040A TCO-2040B, TCO-2040AB, TCA-3050A, TCA-3050B, TCA-3050AB, TCA-3050C, TCA-3050D, TCA-3050CD, TCA-3050AL, TCA-3050BL, TCA-2050A, TCA-2050B, TCA-2050AB, TCB-3080AB, TCB-3080AB, TCB-3080C, TCB-3080D, TCB-3080CD, TCB-3080AL, TCB-3080BL, TCB-2080A, TCB-2080B, TCB-2080AB, TCC-30120A, TCC-30120B, TCC-30120AB, TCC-30120AB 20C, TCC-30120D, TCC-30120CD, TCC-30120AL, TCC-30120BL, TCC-20120A, TCC-20120B, TCC-20120AB,
Capacitive proximity switch LJC12A3-A-Z/AX, LJC12A3-A-Z/BY, LJC12A3-A-Z/AY ,LJC18A3-5-Z/BX, LJC18A3-5-Z/AX LJC18A3-5-Z/BY, LJC18A3-5-Z/AY ,LJC18A3-B-Z/BX , LJC18A3-B-Z/AX, LJC18A3-B-Z/BY LJC18A3-B-Z/AY,LJC24A3-8-Z/BX, LJC24A3-8-Z/AX , LJC24A3-8-Z/BY , LJC24A3-8-Z/AY LJC24A3-8-J/EZ, LJC24A3-8-J/DZ , LJC18A3-B-J/DZ, LJC18A3-5-J/DZ, LJC18A3-5-J/EZ LJC18A3-B-J/EZ,LJC24A3-T-Z/BX, LJC24A3-T-Z/AX, LJC24A3-T-Z/BY , LJC24A3-T-Z/AY LJC24A3-T-J/EZ,LJC24A3-T-J/DZ ,LJC30A3-10-Z/BX, LJC30A3-10-Z/AX ,LJC30A3-10-Z/BY LJC30A3-10-Z/AYLJC30A3-10-J/EZ LJC30A3-10-J/DZ, LJC30A3-H-Z/BX LJC30A3-H-Z/AX LJC30A3-H-Z/BY LJC30A3-H-Z/AY LJC30A3-H-J/EZ LJC30A3-H-J/DZ LJC34A3-K-Z/BX LJC34A3-K-Z/AX LJC34A3-K-Z/BY LJC34A3-K-Z/AY LJC34A3-K-J/EZ LJC34A3-K-J/DZ LJC20A4-10-Z/BXLJC20A4-10-Z/AX LJC20A4-10-Z/BY LJC20A4-10-Z/AY LJC20A4-10-J/EZ LJC20A4-10-J/DZLJC38A4-20-Z/BX LJC38A4-20-Z/AXLJC38A4-20-Z/BY LJC38A4-20-Z/AY LJC38A4-20-J/EZ LJC38A4-20-J/DZLJC80A4-40-Z/BX LJC80A4-40-Z/AXLJC80A4-40-Z/BY LJC80A4-40-Z/AY LJC80A4-40-J/EZ LJC80A4-40-J/DZ LJC12A3-2-Z/BX, LJC12A3-2-Z/AX, LJC12A3-2-Z/BY ,LJC12A3-2-Z/AY, LJC12A3-A-Z/BX